Code No: MS-50501-10-22-M-AE
Technical Specifications
*Reduces the gas from a maximum inlet pressure of 230 bar to 10, 20, or 40 bar outlet pressure.
*Supplied with 4 valve-integrated cylinder connections; suitable for use with single cylinders or cylinder bundles.
*Connections are positioned with 2 on the left and 2 on the right; each group features an independent shut-off valve for isolating the respective line when needed.
*Extension ports on the inlet side allow connection of additional cylinders or bundles via separately purchased valve-integrated connectors.
*All system components are mounted on a high-strength stainless steel panel.
*In oxygen systems, a flame arrestor is installed before the outlet-side ball valve.
*A manual vent valve located after the regulator enables safe gas evacuation before cylinder change or maintenance procedures.
*Check valves positioned behind each of the four cylinder connections prevent backflow and enhance system safety.
*A line pressure gauge located just before the outlet provides pressure visibility even when the main shut-off valve is closed.
*A Ø28 mm copper piping system is installed from the regulator outlet to the system endpoint.
Integrated safety relief valves within and after the pressure regulator allow discharge in case of overpressure or malfunction.