Code No: MS-5050-40-11-M-IS
Technical Specifications
*Reduces the gas from a maximum inlet pressure of 230 bar to 10, 20, or 40 bar outlet pressure.
*Supplied with 2 valve-integrated cylinder connections; suitable for use with single cylinders or cylinder bundles.
*Extension ports on the inlet side allow connection of additional cylinders or bundles via separately purchased valve-integrated connectors.
*All system components are mounted on a high-strength stainless steel panel.
*Equipped with an integrated gas heater to prevent freezing issues common with mixed gases and CO₂ applications.
*A manual vent valve located after the regulator enables safe gas evacuation before cylinder change or maintenance procedures.
*Check valves positioned behind both cylinder connections prevent backflow and enhance system safety.
*A line pressure gauge located just before the outlet provides pressure visibility even when the main shut-off valve is closed.
*A Ø28 mm copper piping system is installed from the regulator outlet to the system endpoint.
Integrated safety relief valves within and after the pressure regulator allow discharge in case of overpressure or malfunction.
.gif)