Code No: MS-5050-10-22-M-IS
Technical Specifications
*Reduces gas from a maximum inlet pressure of 230 bar to an outlet pressure of 10, 20, or 40 bar.
*Equipped with 4 cylinder connections with valves; suitable for use with individual cylinders or cylinder bundles.
*The cylinder connections are arranged with 2 on the left and 2 on the right; each group includes an independent shut-off valve allowing isolation of the line when needed.
*Additional cylinders or bundles can be connected via the inlet extension ports by purchasing valve-equipped connections.
*All components are mounted on a high-strength stainless steel panel.
*An integrated gas heater is included to prevent freezing issues common with CO₂ and mixed gases.
*A manual vent valve after the regulator allows for safe gas evacuation before cylinder replacement or maintenance.
*Check valves located behind all four cylinder connection valves prevent reverse gas flow, enhancing system safety.
*A line pressure gauge positioned right before the outlet displays internal pressure even when the main line valve is closed.
*From the regulator to the outlet, the system is fitted with Ø28 mm copper piping.
*Overpressure relief valves located on and after the regulator ensure safe pressure discharge in case of malfunction.